GUARD INSTALL & CAPPING CUT TEMPLATE

Sensor Guard Installation

  • Sensor guard installation should be done after the initial calibration and leveling of the      sensor.
  • Remove the Guard Assembly from the package and using the button head allen bolts,         tighten the support braces to the top plate.
  • Take the aluminum mounting support brackets and finger tighten the hardware to               them. 
  • Position the guard over the sensor allowing a minimum of ½” gap between the top              plate and the sensor.
  • With the guard level from front to back and from and side to side, use a black marker          and mark where the lag bolts will be screwed in. 
  • Using the supplied lag bolts fasten all of the mounting angles into place.
  • Tighten the guard into place. 
  • After the sensor guard has been installed a hole will need to be made in the capping.
  • Using the template below mark the capping based on the actual location of the sensor.
  • This hole, when done, should yield ample border to safely remove the capping without      damaging the sensor.